本文へ移動

New product

Inverter unification monitoring software

The need of the inverter monitoring

facilities preventive maintenance
  • Prevention of line rate of operation drop by the trouble foresight
  • Maintenance cost reduction by the appropriate maintenance timing
  • Preventive maintenance function addition to operation facilities
          
Preventive maintenance of the whole facilities is demanded
 
By inverter monitoring
  The abnormal vibration of the product line/device and the monitoring of the load change,
  In watching the output data change of the inverter driving facilities
  It can come true.
 facilities trouble analysis
  • Maintenance by the trouble mode judgment
  • Preventive measures development by the change of state analysis to lead to trouble
  • Influence on other facilities judgment at the time of the trouble
          
The load change monitoring every facilities is demanded
 
By inverter monitoring
 A trouble judgment and the maintenance necessity or not of the device,
 The output electric current change of the inverter driving a device
 It can come true by watching a frequency change.
 
 unification monitoring
  • It is a limit for the simple substance facilities monitoring every inverter
  • It is management cost reduction by intensive monitoring by the networking
  • Data analysis between facilities at the time of the trouble
       
A function to watch the whole product line in a mass is demanded
 
Monitoring simple by inverter unification monitoring software

Inverter unification monitoring software enable it

inverter inside data collection
  • The operation data (ON/OFF level such as a movement mode, the abnormal flag)
  • The output data (analog level such as a frequency, torque, the voltage, an electric current, the electricity)
  • Constant period collection → CSV file preservation
  • Plural inverter connection
 
real-time monitoring
  • Present value indication
  • Trendy indication
  • Abnormal judgment, the log output

Corresponding inverter

 Yaskawa Electric
 G7 series /A1000 series /V1000 series
 
 Mitsubishi Electric
 FREQROL A800
 
 FUJI ELECTRIC
 FRENIC-Mini
※There is unconnected RS-485 port
//ncs-eng.co.jp/en/files/libs/78/201903221732358660.png  For details, please refer to a PDF file than the following link.
Nicosu Corporation 
2-30, Hatabumiyanoshita-chou, Shimonoseki-city,
Yamaguchi 751-0829 JAPAN
TEL.+81-83-251-1180
FAX.083-250-6638
2024年10月
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
2024年11月
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
  • Summer holiday (8/10-8/18)
  • The employee training (9/26-9/28)
TOPへ戻る